Reverse Osmosis

Brackish Water HP Series

High Pressure

Greater rejection of salts for critical brackish water applications.

Performance Specification

Operating data from the original catalog

Test pressure 150 psi (10.3 bar), NaCl concentration 2,000 ppm, recovery rate 15%, temperature 25°C, pH 7.

PropertyROMG 4040 HPROMG 8040 HP
Active Membrane7.9 m²41 m²
Average Permeate2,200 gpd (8.5 m³/d)10,500 gpd (38.4 m³/d)
Stable Rejection98.5%98.1%
Minimum Rejection98.1%97.7%
Spacer Mesh Thickness28 thou (0.72 mm)28 thou (0.72 mm)

Limits and Operating Conditions

ROMG 4040 HP

ParameterValue
Max. Feed Water Flow Rate16 gpm (3.6 m³/h)
Max. Operating Pressure600 psi (41 bar)
Max. Feed Water Temperature40°C
Max. Feed Water SDI15<3
pH range during continuous operation2~11
pH range during chemical cleaning2~12
Residual chlorine concentration<0.1 ppm
Max. pressure drop of a single element10 psi (0.07 MPa)
Max. Turbidity NTU1.0

Limits and Operating Conditions

ROMG 8040 HP

ParameterValue
Max. Feed Water Flow Rate70 gpm (16 m³/h)
Max. Operating Pressure600 psi (41 bar)
Max. Feed Water Temperature40°C
Max. Feed Water SDI15<3
pH range during continuous operation2~11
pH range during chemical cleaning2~12
Residual chlorine concentration<0.1 ppm
Max. pressure drop of a single element10 psi (0.07 MPa)
Max. Turbidity NTU1.0